The temperature characteristic of temperature control floor for different regions of the data center to provide tailored floor ventilation solutions, the effective realization of room floor and air conditioning system of perfect combination. Temperature control floor to the server side of the intake temperature as the target, you can set the starting temperature and working temperature, the system according to the temperature sensor acquisition signal to achieve the automatic speed of the fan speed. When the temperature sensor collection temperature is less than the initial temperature, the system is in a stagnant state, is greater than the starting temperature, the system of the wind turbine to achieve linear speed, greater than the cut-off temperature, the system to maintain full speed running state.
The floor by the quality of the steel and all welded steel, concentrated load more than 1 tons, more than 3 tons of uniformly distributed load. The surface wind rate is high, suitable for different customer requirements. The floor has a high accuracy and can be used directly with different materials.
Fan system selection of international well-known brands, high quality assurance and durability, to achieve more than 10 years of safe service life.
Temperature control floor features:
1, the efficiency of the focus, the use of variable air volume, to achieve the cold temperature distribution
2, do not need to modify the current air conditioning system, relying on the air delivery of cold, without the risk of condensation water
3, green environmental protection, to achieve energy saving and emission reduction, improve energy efficiency, reduce capital investment and produce superior investment returns
4, can provide high capacity air quantity, and can transmit to the whole server, the application of high flexibility, to achieve the engine room layout and ventilation rate corresponding to upgrade
5, the use of the most advanced EC axial flow fan than the AC fan energy saving 30% or more, the guide type to send wind grid floor, guarantee the highest air supply rate
6 with Lan port, to achieve remote observation and setting parameters, convenient control
7, with temperature sensor, detection of the highest temperature, control more accurate, to achieve dual power supply, to ensure the safety of the engine room equipment
8, intelligent ventilation floor can support IT heat load 22kW 0-, standard modular, fast, easy to install, high accuracy, temperature measurement fast response, optional monitor interface, the user can set temperature, high reliability design, the maximum temperature of each cabinet can be visual inspection
9, using the scene
Heat: because of various causes of local hot spots
Far: usually far from air conditioning
Partial: air conditioning of the cold air is not easy to send
Stop: the bottom of the line bracket and other barriers, ventilation is not smooth